In-situ gas analyzers

Real-time gas analysis directly within the process
Reliable measurement technology that allows the devices to be mounted directly at the measurement site: In-situ gas analyzers take measurements directly within the process under system conditions. These analyzers are primarily characterized by their very minimal maintenance requirements and extremely short response times. In-situ gas analyzers from SICK are available in two different versions:
• The cross-duct version for representative measurement results across the entire duct diameter
• The measuring probe version, optimized for single-sided gas duct installation
Filter by:
7 results:
- Direct, fast in-situ measurement
- No gas sampling, no gas transport, no gas conditioning
- Up to four measurands at the same time, plus process temperature and pressure
- DOAS evaluation methods
- Numerous independent measuring ranges with consistent accuracy
- Automated self-test function (QAL3) without test gases
- Overpressure encapsulated type for Ex-zone 2
For efficient control of combustion and drying processes
- Dynamic humidity correction
- Fast in-situ measurement directly in the process
- Simultaneous determination of up to three gas components, temperature, and pressure
- No gas sampling and conditioning
- Gas testable version of measuring probe available
- Integrated self-test and control functions
Efficient process analysis – even under difficult conditions
- High selectivity due to high spectral resolution
- Short response times
- No calibration required
- No moving parts: minimal wear and tear
- No gas sampling or conditioning required
- Overpressure encapsulated design for ATEX Zone 2
- Electrochemical cell with extremely long service life due to innovative protection mechanisms
- Self-monitoring electrochemical cell
- Fully automated adjustment mechanism integrated into the control unit
- Version for high temperatures available
- ZIRKOR remote app for remote access to the analyzer
- Very short response time
- Suitability-tested according to EN 15267
- Ex version for ATEX/IECEx, Zone 1 and Zone 21
CO measurement for emission monitoring and process control
- Representative measurement along the duct diameter
- Operation via control unit
- Short response times
- Verifiable with gas-filled cell; gas-testable probe with test gas
- Measurement cell with long service life due to high-quality processing
- Measurement cell self-monitoring
- Version for high temperatures available
- ZIRKOR remote app for remote access to analyzer
- Very short response time